Setup with the core objective to design and develop\upgrade technology and reliability of substation equipment through Diagnostic and Life extension techniques. State of the art High Voltage test facility for Onload Tapchanger upto 765 kv and other electrical engineering equipment.
The Centre is also involved in Research and Development of Digital substation automation systems, Power Quality improvement products, Power Electronic Capacitors, Transformer explosion prevention and fire safety, Dielectric fluid, different material.
Previous
Next
Test facility of the Research and Development centre are recognised by Ministry of Science and Technology, Department of Scientific and Industrial Research (DSIR), Government of India; National Accreditation Board for Testing and Calibration Laboratories (NABL) for the following:
ONLOAD TAPCHANGERS
UPTO 765 KV AND DRIVE MECHANISMS FOR TAP CHANGERS
(ISO accredited test facility)
Partial discharge test
Chopped wave lightning Impulse
Short Circuit current
Switching Impulse
Temperature Rise
Applied Voltage (HV)
Tan Delta
Auxiliary Circuit Insultation
Switching Tests includes Service duty and Breaking capacity test
Mechanical Endurance
Transition impedance test
Mechanical load test of Drive Mechanism
Pressure tests
Sequence test
Vacuum tests
Mechanical test of drive mechanism
Tightness tests
Contact Resistance
Lightning Impulse test
Overrun test of motor drive
TRANSFORMER EXPLOSION PREVENTION FIRE EXTINGUISHING SYSTEM
(Inhouse developed test facility)
Leakage test
Flow rate test for
Transformer
Conservation Isolation valve
Auxiliary Circuit
Insulation test
System Activation Test
System Response test
Auxiliary Supply Voltage test
ELECTRONIC PRODUCTS
(ISO accredited test facility)
Dielectric tests
Voltage proof tests
Climatic tests
Endurance tests
Capacitance test
Dielectric loss measurement tests
POWER ELECTRONIC AND POWER FACTOR CORRECTION CAPACITORS
(Inhouse developed test facility)
Thermal stability test
Self-Healing test
Discharge test
Destruction test
Aging test
Over pressure test
Dielectric test between terminal
Dielectric test between terminal and Container
Charge/Discharge test
Insulation Resistance
Capacitance measurement at rated Voltage
Tan Delta
INSULATED BUSHING FROM 1KV TO 36KV
(ISO accredited test facility)
Dry Power Frequency test
Dry Lightening Impulse test
Temperature rise test
Verification of dimensions
Partial Discharge test
Tightness test
TEST LAB SERVICES
Although test lab activities are mainly confined to products of the company, the facility is available to others for Transformers, Bushings, circuit breakers on request.
REACH US
THANK YOU!